Data-drive™

Guide

PID lists

Tick channels for the live view and logger. Custom PIDs use your formula on the response bytes.

11 selected · The set you actually need on a drive: rpm, speed, load, trims, airflow.

Engine

  • Calculated engine load

    0104 · A*100/255 · %

  • Engine coolant temperature

    0105 · A-40 · °C

  • Intake manifold pressure

    010B · A · kPa

  • Engine RPM

    010C · ((A*256)+B)/4 · rpm

  • Vehicle speed

    010D · A · km/h

  • Timing advance

    010E · (A/2)-64 · °

  • Intake air temperature

    010F · A-40 · °C

  • Throttle position

    0111 · A*100/255 · %

  • Run time since start

    011F · (A*256)+B · s

  • Barometric pressure

    0133 · A · kPa

  • Absolute load value

    0143 · ((A*256)+B)*100/255 · %

  • Relative throttle position

    0145 · A*100/255 · %

  • Ambient air temperature

    0146 · A-40 · °C

  • Absolute throttle position B

    0147 · A*100/255 · %

  • Accelerator pedal position D

    0149 · A*100/255 · %

  • Accelerator pedal position E

    014A · A*100/255 · %

  • Commanded throttle actuator

    014C · A*100/255 · %

  • Engine oil temperature

    015C · A-40 · °C

  • Driver demand torque

    0161 · A-125 · %

  • Actual engine torque

    0162 · A-125 · %

  • Engine reference torque

    0163 · (A*256)+B · Nm

Fuel

  • Short term fuel trim B1

    0106 · (A-128)*100/128 · %

  • Long term fuel trim B1

    0107 · (A-128)*100/128 · %

  • Short term fuel trim B2

    0108 · (A-128)*100/128 · %

  • Long term fuel trim B2

    0109 · (A-128)*100/128 · %

  • Fuel pressure

    010A · A*3 · kPa

  • Mass air flow

    0110 · ((A*256)+B)/100 · g/s

  • Fuel rail gauge pressure

    0123 · ((A*256)+B)*10 · kPa

  • Wideband lambda B1

    0124 · ((A*256)+B)/32768 · λ

  • Fuel tank level

    012F · A*100/255 · %

  • Wideband lambda B1 voltage

    0134 · ((A*256)+B)/32768 · λ

  • Commanded equivalence ratio

    0144 · ((A*256)+B)/32768 · λ

  • Engine fuel rate

    015E · ((A*256)+B)*0.05 · L/h

Emissions

  • O2 sensor B1S1 voltage

    0114 · A/200 · V

  • O2 sensor B1S2 voltage

    0115 · A/200 · V

  • Distance with MIL on

    0121 · (A*256)+B · km

  • Commanded evaporative purge

    012E · A*100/255 · %

  • Warm-ups since codes cleared

    0130 · A

  • Distance since codes cleared

    0131 · (A*256)+B · km

  • Catalyst temp B1S1

    013C · ((A*256)+B)/10-40 · °C

Electrical

  • Control module voltage

    0142 · ((A*256)+B)/1000 · V

41 SAE mode 01 sensors plus your custom entries. Unused channels stay off the logger so CSV files stay readable.